EasyManua.ls Logo

Skyjack SJ30AJE - Page 175

Skyjack SJ30AJE
190 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
175
SJ30AJE, SJ30ARJE 196274AF
Base Section 5 – Procedures
Flash
Code
DisplayedonMDI ProbabableCause Remedy
0XA89 PUMPVACCNOTOK
Thepumpaccelatorvalueishigher
thantheminmumvaluerecorded,
andthelift/lowerswitchesareopen.
1.Checkwiring.
2.AquirejoystickVACC.
3.Replacejoystick/switch.
Replacecontroller
0XA92 CURRENTGAIN InternalControllercheck
1.Cyclekeyswitch
2.Factoryreset(ClearEeprom)
3.Replacecontroller.
0XA96 ANALOGINPUT Analogtodigitalfailure
Cause:
ThisalarmoccurswhentheA/Dconversionoftheanalog
inputsgivesfrozenvalue,onalloftheconvertedsignals,
formorethan400msec.Thegoalofthisdiagnosisisto
detectafailureoftheA/Dconverteroraprobleminthe
codeflowthatomitstherefreshingoftheanalogsignal
conversion.
Troubleshooting:
Iftheproblemoccurspermanentlyitisnecessaryto
Replacecontroller
0XA99 SLIPPROFILE
Errorontheparametersoftheslip
profilesetting.
1.Cyclekeyswitch
2.Factoryreset(ClearEeprom)
3.Replacecontroller.
ZAPI MDI-CAN Controller Master Codes (continued)

Table of Contents