75
SJ6832 RTE
Refuel the Hybrid Power Pack (HPP) with Diesel Section 6 – Additional Procedures
6.9-1 Deploy the maintenance support
1. Remove all personnel and material from the
platform.
WARNING
Look for overhead obstructions or other possible
hazards around the MEWP when you raise the
platform. Do not lower the platform unless the area
below is clear of personnel and obstructions. If
you do not obey, there is a risk of death or serious
injury.
2. Raise the platform until there is adequate
clearance to deploy the maintenance support.
3. Deploy the maintenance support from the
storage bracket into a vertical position.
4. Make sure that the scissors assembly area has
no obstructions.
5. Lower the platform until the bottom end of the
maintenance support touches the crossbar and
the platform stops.
6. Turn the main power disconnect switch to the off
position.
6.9-2 Store the maintenance support
WARNING
Look for overhead obstructions or other possible
hazards around the MEWP when you raise the
platform. Do not lower the platform unless the area
below is clear of personnel and obstructions. If
you do not obey, there is a risk of death or serious
injury.
1. Turn the main power disconnect switch to the on
position.
2. Raise the platform until there is adequate
clearance to retract the maintenance support.
3. Retract the maintenance support into the
storage bracket.
4. Fully lower the platform.
6.10 Refuel the Hybrid Power
Pack (HPP) with Diesel
WARNING
Explosion hazard. Only refuel the MEWP in a well-
ventilated area, away from open flame and other
sources of ignition, approved by your employer
and/or supervisor. Always have an approved fire
extinguisher that you can easily access. If you do
not obey, there is a risk of death or serious injury.
IMPORTANT
Before you use the MEWP, make sure that there is
sufficient fuel for the estimated task.
1. Put all the power connections in the off position.
2. Let the HPP cool for a minimum of 3 minutes.
3. Remove the fuel cap.
WARNING
Environmental hazard. Immediately remove diesel
fuel and hydraulic fluid spills and leaks with rags.
Discard these rags in accordance with national,
state/provincial/territorial, and local regulations.
Spilled fluids can damage the environment. When
spilled fluids go into the water (for example, a
sewage system, streams, rivers, or other surface
water), they can kill aquatic life.
4. Carefully fill the fuel tank with ultra low sulfur
diesel fuel. Make sure that there are no spills.
5. Put the fuel cap back on and make sure it closes
tightly.
6. Do an inspection of the fuel system for leaks.
Clean away spilled fuel.
7. Discard the wipes or rags in an approved