Technical Data SMA Solar Technology AG
64 SB13_21TL-IA-IEN121060 Installation Guide
Protective Devices
* optional
General Data
Maximum cable length at cable diameter of
1.5 mm²
11 m
Maximum cable length at cable diameter of
2.5 mm²
18 m
DC reverse-polarity protection Short circuit diode
Input-side disconnection device* Electronic Solar Switch
DC overvoltage protection Thermally monitored varistors
AC short-circuit current capability Current control
Grid monitoring SMA Grid Guard 2.1
Maximum permissible fuse protection 16 A
Ground fault monitoring Insulation monitoring: R
iso
> 1
All-pole sensitive residual current monitoring unit Available
Width x height x depth 440 mm x 299 mm x 214 mm
Width x height x depth with Electronic Solar
Switch
440 mm x 339 mm x 214 mm
Weight 16 kg
Length x width x height of packaging 532 mm x 392 mm x 318 mm
Weight with packaging 21.2 kg
Climatic category according to IEC 60721-2-1 4K4H
Operating temperature range 25 °C +60 °C
Maximum permissible value for relative humidity,
non-condensing
100 %
Maximum operating altitude above mean sea
level
2 000 m
Noise emission, typical 33 dB(A)
Power loss in night operation 0.1 W
Topology Transformerless
Cooling concept Convection
Degree of protection according to IEC 60529 IP65
Protection class according to IEC 62103 I