SMA Solar Technology AG Technical Data
Installation Guide SB13_21TL-IA-IEN121060 65
* EN 50438: Does not apply to all country standard deviations of EN 50438
G83/-1-1: Valid from firmware version 4.20
Climatic conditions in accordance with IEC 60721-3-4, installation type C, class
4K4H
Climatic conditions in accordance with IEC 60721-3-4, transport type E, class 2K3
Features
Electronic Solar Switch (optional)
Country standards, as of 03/2012* VDE 0126-1-1
UTE C15-712
AS 4777
C10/11
PPDS
EN 50438
G83/-1-1
RD1663/661-A
Extended temperature range − 25 °C … +60 °C
Extended humidity range 0 % … 100 %
Extended air pressure range 79.5 kPa … 106 kPa
Temperature range − 25 °C … +70 °C
DC connection SUNCLIX DC connector
AC connection AC connector
Display LC text display
Bluetooth
®
Wireless Technology Optional
RS485, galvanically isolated Optional
Electric service life in the event of a short circuit,
with a nominal current of 35 A
A minimum of 50 switching operations
Maximum switching current 35 A
Maximum switching voltage 800 V
Maximum PV power 11 kW
Degree of protection when plugged IP65
Degree of protection when unplugged IP21