Displays and Messages Status Messages on the LCD
7-12 SMA America SB3000US-4000US-11-SE1607
Operation Messages
The LCD continuously scrolls through all relevant operating data. Each message
(MSG) is displayed for 5 seconds, after all messages have been displayed the LCD
repeats from the beginning.
Energy produced today
and current operating mode
E-today 3.86kWh
Mode MPP
MSG #1 “E-Today“ (total energy produced on this day)
is displayed together with the current operating mode:
Gridtype and phase-to-neutral volt-
ages
Gridtype - 208V
L1 120V L2 120V
MSG #2 Nominal grid voltage configuration and
actual line-to-neutral voltage measurements:
AC power
and DC voltage
Pac 3200W
Vpv 380V
MSG #3 Actual AC power output and DC input
voltage:
Total energy yield
and total operating hours
E-total 724.4kWh
h-total 512h
MSG #4 Accumulated energy yield of the device since
installation and the total operating hours:
Note: The screens may also be scrolled through manually
by repeatedly knocking on the lid of the inverter. Each knock
advances the screen to the next message.