SMA America, LLC 6 Electrical Connection
Installation Manual SB30-40-US-IA-en-33 45
To negatively ground the DC input, insert the fuse extractor with ground fuse into the fuse holder
and insert the jumper into the pin header:
Insert the fuse extractor with ground fuse into the
upper fuse holder.
Insert the jumper into the upper pin, labeled
"NEG", of the pin header.
To positively ground the DC input, insert the fuse extractor with ground fuse into the fuse holder
and insert the jumper into the pin header:
Insert the fuse extractor with ground fuse into the
lower fuse holder.
Insert the jumper into the lower pin, labeled
"POS", of the pin header.