EasyManua.ls Logo

Smartgen HGM6120U

Default Icon
39 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HGM6100U Series Automatic Control Module
HGM6100U Automatic Genset Controller ISSUE 2014-10-28 Version 1.2 Page 7 of 39
3 SPECIFICATION
Items Contents
Working Voltage DC8.0V to DC35.0V, continuous
Power Consumption <3W(Standby mode: ≤2W)
AC System
3P4W
3P3W
1P2W
2P3W
AC15V - AC360 V (ph-N)
AC30V - AC620 V (ph-ph)
AC15V - AC360 V (ph-N)
AC15V - AC360 V (ph-N)
AC Alternator Frequency 50Hz/60Hz
Rotate speed sensor Voltage 1.0V to 24V (RMS)
Rotate speed sensor Frequency 10,000 Hz (max.)
Start Relay Output 16 A DC28V at supply voltage
Fuel Relay Output 16 A DC28V at supply voltage
Programmable Relay Output 1 7 A DC28V at supply voltage
Programmable Relay Output 2 7 A 250VAC volt-free output
Programmable Relay Output 3 16 Amp 250VAC volt-free output
Programmable Relay Output 4 16 A 250VAC volt-free output
Overall Dimensions 197 mm x 152 mm x 47mm
Panel Cutout 186mm x 141mm
C.T. Secondary Current 5A (rated)
Working Condition Temperature: (-25~70C; Humidity: (20~93)%
Storage Condition Temperature: (-25~+70)ºC
Protection Level IP55 Gasket
Insulation Intensity
Apply AC2.2kV voltage between high voltage
terminal and low voltage terminal;
The leakage current is not more than 3mA within
1min.
Weight 0.56kg

Related product manuals