19
http://support.weathermatic.com
RAIN: The rain selection is on/o toggle to override the SLW
sensor feature for selected zones. Factory default is ON for all
zones.
FREEZE: The freeze selection is on/o toggle to override the
SLW freeze sensor feature for selected zones. Factory default is
ON for all zones.
6.6 Min Def
This feature allows a Minimum Deficit to be set. The feature
requires that a zone deficit be greater than the MIN DEF setting
in order to run during a scheduled program. The setting is
global for all zones in SMART. The range for the global setting is
0.00 to 0.50 inches. The factory default is 0.15 inches.
6.7 Sensor
Sensor is an ON/OFF toggle to override the SEN terminals rain/
freeze functions on selected zones. Factory default is ON.
6.8 Set Manual Run/Soak
The purpose of Run/Soak is to break up long run times that
often cause wasteful runo. The Run/Soak is programmable for
each program if you are using the BASIC watering mode. Note:
If you are using SMART, these inputs are not used since the Run/
Soak period is automatically calculated.
Use NEXT button to access RUN time allowed before the zone
watering pauses for the specified soak time. Use PGM button
to select program. Use UP and DOWN buttons to set RUN time
from OFF to 30 minutes (SmartLine™ controller default is OFF).
Use NEXT button to access soak time required for water to
infiltrate into soil before zone watering is continued. Use the UP
and DOWN buttons to set soak time from 1 minute to 2 hours in
one-minute increments.
6.9 Ds Time
Your SmartLine® controller can automatically adjust the time for
daylight saving time (DST). The factory default setting is OFF
and has been preset for the current USA schedule. To turn DST
adjust ON, press the next button at DS TIME, the NEXT button at
ON/OFF then select ON.
The DS Time feature can be customized to match any
international DST schedule. Press the NEXT button at DS
TIME in advanced functions. Select DS SETUP and press the
NEXT button again. You will be prompted to enter the START
schedule (time of day is moved ahead 1 hour per START
schedule), and the STOP schedule (time of day is moved back
1 hour per STOP schedule). DST start and stop are formatted
with the the Week (first, second, third, last), the Day (Sun-Sat)
and the Month (Jan-Dec). All DS Time adjustments are made at
2 am. To return the DS Time schedule back to the USA factory
default, use the US DEFLT option.