Drive Startup Manual M1000
March 5, 2020 ©2020 Smartrise Engineering, Inc. All Rights Reserved Page 11
Perform the InitPoleEstPrms for PM Tuning Mode (U9).
BEGIN ALIGNMENT to Yes but DON’T PRESS THE ENTER BUTTON.
Turn on DIP 6A. The M contactor automatically engages, and the screen displays
TUNE command. Press the Enter Button on the drive to start the alignment.
NOTE: If this fails with an angle deviation fault, a non-rotational alignment should not be
performed.
Did the InitPoleEstPrms for PM Tuning Mode (U9) fail for angle deviation?
a. If the InitPoleEstPrms for PM Tuning Mode (U9) fail for angle deviation, see the
Magnetek M1000 AC Elevator Drive for PM Autotune then go to step 9.
b. If the InitPoleEstPrms for PM Tuning Mode (U9) did not fail angle deviation, turn off
DIP 6A and go to step 8.
Perform the PolePos-norotate for PM Tuning Mode (U9).
BEGIN ALIGNMENT to Yes but DON’T PRESS THE ENTER BUTTON.
Turn on DIP 6A. The M contactor automatically engages, and the screen displays
TUNE command. Press the Enter Button on the drive to start the alignment.
Did the PolePos-norotate for PM Tuning Mode (U9) pass?
a. If the PolePos-norotate for PM Tuning Mode (U9) did not pass, go to step 10.
b. If the PolePos-norotate for PM Tuning Mode (U9) passed, turn off DIP 6A and the
process ends.
If you are running on construction/inspection and run into the following:
If the motor is running slowly/uncontrolled and drawing high current:
Swap Encoder Connect (C1)
Verify that the encoder is working
If the elevator is running at controlled/proper speed but in the opposite direction of
what it is being told:
Swap both the Encoder Connect (C1) and Motor Rotation (C1). Go to step 8.
Induction Motor Key Drive Parameters
The table below lists the Parameters for the A1 Drive.
Table 8: Parameters for A1 Drive
Parameter Description Default Units Suggested Adjustments
Car Spd
Elevator contract
speed
400
fpm
Set to the speed the elevator will be
certified at.