Drive Startup Manual M1000
March 5, 2020 ©2020 Smartrise Engineering, Inc. All Rights Reserved Page 15
Proper Direction
Make sure the car is moving in the same direction as the control switch on the Run Bug.
• If the car is moving only in one direction, swap the ENC 1 ROT DIRECT (C1) in the
Magnetek Drive to forward or reverse for PM application. For induction application,
swap A and A/ encoder wires.
• If the car is moving in the opposite direction, swap both direction of the ENC 1 ROT
DIRECT (C1) and MOTOR ROTATION (C1) for PM application. For induction application,
swap A and A/ encoder wires.
Brake Not Lifting
If the brake is not picking, make sure that the brake is wired according to C4 Controller sheet 05
Brake Connection and if there is a second brake installed, verify that the EB terminal is
jumpered to the terminal. See the C4 Controller sheet 01 – Getting Started for more
information.
If the brake has the proper voltage check the following:
• During a run command, check the DC voltage between points K1 / K2 and J1 / J2 if
secondary brake is installed. Verify the voltages are also at the brake coil(s) when
commanded to pick.
• Verify that the actual brake voltage matches the brake coil voltage shown on the C4
Controller sheet 01 – Getting Started Parameter table.