EasyManuals Logo

Smartrise C4 Startup Manual

Default Icon
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #23 background imageLoading...
Page #23 background image
Drive Startup Manual M1000
March 5, 2020 ©2020 Smartrise Engineering, Inc. All Rights Reserved Page 15
Proper Direction
Make sure the car is moving in the same direction as the control switch on the Run Bug.
If the car is moving only in one direction, swap the ENC 1 ROT DIRECT (C1) in the
Magnetek Drive to forward or reverse for PM application. For induction application,
swap A and A/ encoder wires.
If the car is moving in the opposite direction, swap both direction of the ENC 1 ROT
DIRECT (C1) and MOTOR ROTATION (C1) for PM application. For induction application,
swap A and A/ encoder wires.
Brake Not Lifting
If the brake is not picking, make sure that the brake is wired according to C4 Controller sheet 05
Brake Connection and if there is a second brake installed, verify that the EB terminal is
jumpered to the terminal. See the C4 Controller sheet 01 Getting Started for more
information.
If the brake has the proper voltage check the following:
During a run command, check the DC voltage between points K1 / K2 and J1 / J2 if
secondary brake is installed. Verify the voltages are also at the brake coil(s) when
commanded to pick.
Verify that the actual brake voltage matches the brake coil voltage shown on the C4
Controller sheet 01 Getting Started Parameter table.

Other manuals for Smartrise C4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Smartrise C4 and is the answer not in the manual?

Smartrise C4 Specifications

General IconGeneral
BrandSmartrise
ModelC4
CategoryController
LanguageEnglish

Related product manuals