FLEXIBLE ASSEMBLY SYSTEM FAS200
User Manual for FAS200 - 21 -
Control panel:
Start, stop, reset pushbuttons. Emergency stop button, main switch on/off,
mode selector (auto-man), no material indicator and error pilot indicator.
Composition of module manipulators:
Body feeder
Magazine capacity: 12 bodies.
Actuators:
- Double-acting pusher cylinder Ø16, Stroke: 100mm (CD85N16-100-B),
with flow regulators and initial-end position detectors. Controlled by 5/2 way
monostable solenoid valve.
Sensors:
- Reed type magnetic detectors (D-C73L).
- Inductive sensor OMRON (E2A-M12KS04-WP-B1).
Position verification
Actuators:
- Double-acting cylinders Ø12, Stroke: 50mm (CD85N12-50-A), with flow
regulators and end position detector. Controlled by 5/2 way monostable
solenoid valve.
Sensors:
- Reed type magnetic detector (D-A73CL).
Transfer manipulator
Actuators:
- Rectangular section pusher cylinder Ø25, Stroke: 200mm (MDUB25-
200DMZ), with flow regulators and end position detector. Controlled by 5/2 way
monostable solenoid valve.
Sensors:
- Reed type magnetic detector (D-A93L).