300
300051
32
300
Options
DIN rail AXT100-DR-
∗
For , enter a number from the No. line in the table on page 22.
Refer to the dimension drawings on pages 20 to 22 for the mounting
dimensions.
DIN rail mounting adapter LEC-3-D0
∗ With 2 mounting screws
This should be used when the DIN rail mounting adapter is
mounted onto a screw mounting type controller afterward.
Communication cable for controller setting
Hardware Requirements
q Communication cable JXC-W2A-C
<Controller setting software/USB driver>
· Controller setting software
· USB driver (For JXC-W2A-C)
Download from SMC’s website: https://www.smc.eu
∗ It can be connected to the controller directly.
w USB cable LEC-W2-U
∗ Windows
®
7, Windows
®
8.1, and Windows
®
10 are registered
trademarks of Microsoft Corporation in the United States.
OS Windows
®
7, Windows
®
8.1, Windows
®
10
Communication
interface
USB 1.1 or USB 2.0 ports
Display 1024 x 768 or more
Teaching box
LEC
T1 3
J
G
Teaching
box
Initial language
J
Japanese
E
English
∗
The displayed language can be
changed to English or Japanese.
Cable length [m]
3
3
Specifications
Item Description
Switch Stop switch, Enable switch (Option)
Cable length [m] 3
Enclosure IP64 (Except connector)
Operating temperature range [°C]
5 to 50
Operating humidity range [%RH]
90 or less (No condensation)
Weight [g] 350 (Except cable)
Stop switch
G
Equipped with stop switch
Enable switch
—
None
S
Equipped with enable switch
∗ Interlock switch for jog and test
function
Conversion cable P5062-5 (Cable length: 300 mm)
∗ To connect the teaching box (LEC-T 1 -3 G) or communication cable
for controller setting (LEC-W 2 A-C) to the controller, a conversion cable
is required.
A set which includes a communication cable (JXC-W2A-C) and
a USB cable (LEC-W2-U)
e Controller setting kit JXC-W2A
25
JXCE1/91/P1/D1/L/M1 Series
Enable switch
(Option)
Stop
switch