POSSIBLE
TECHNICIAN
ACTION
Detergent pump P1 batching.
Set the ml/l, the default setting is 3 = 3 ml/l.
(The max. setting is 10 = 9.8 ml/l)
Increase/decrease the setting with the Select buttons.
Rinse aid pump P2 batching.
Set the ml/l, the default setting is 0,5 = 0,5 ml/l.
(The max. setting is 10 = 1.35 ml/l)
Increase/decrease the setting with the Select buttons.
Water hardness
Set the hardness in °f, in steps of 5. Range: 0-65°f. The
default is 40°f.
Attention: Make sure that the value corresponds to the
actual hardness of the water supply.
Additive dispensing type
- dd (powder detergent dispenser)
- PP (peristaltic pumps)
The default is “DD”. Enabling the peristaltic pumps
disables the powder dispenser.
Entering the configuration menu
Access to this menu is reserved for technicians for
setting up the dishwasher, and is password protected.
Table of peristaltic pump batching settings:
Move from one parameter to the next with A and B ; change the settings with and and
confirm them by holding down .
To quit Set mode, hold down .ù
6.1.3 Parameter “SET 3“