16
EEWB330B
4.4 SELECTING OPERATOR PREFERENCES
4.4.1 FINE BALANCING MODE
This balancer measures with the maximum precision
availa ble all the time, 1g / 0.05 oz, however values
below 5g / 0.25 oz are shown as zero while in the nor-
mal operating mode. Values exceeding 5g / 0.25 oz
are rounded to the amount of the nearest commercial
wheel weight.
Press the FINE button to advance to the display resolu-
tion between 5g / 0.25 oz and 1g / 0.05 oz.
4.4.2 OUNCE/GRAMS CONVERSION
When the machine is fi rst turned on it is preset to disp
lay
the imbalance in ounces.
Press the MODE button to advance to select ounces
or grams.
Select Enter to save selection.
4.4.3 RIM DIAMETER IN MILLIMETERS
The rim diameter is normally displayed in inches,
however if the value in millimeters is desired. Press
the MODE button until “PAX/mm” is NOT illuminated
to display in inches, when lit the unit displays in mm.
4.5 ENTER RIM PARAMETERS
4.5.1 Rim Distance (offset)
- Move the rim offset
arm to the edge of the rim, touch the pointer to the
rim edge as illustrated in Figure 19 and hold steady
for about a second. The beeper will sound when the
distance and diameter values are calculated and en-
tered. Return the arm to its fully in and down position
on the balancer. Do not allow the measurement arm to
“dangle” down in front of the balancer
.
W
Figure 21
Figure 19
Figure 20
4.5.2. Measure/Enter rim width using rim width
caliper. Measure
wheel where corrective clip-on weight
would be applied, Figure 20.
Press the Width entry key, Figure 21-W, and enter the
measured width by pressing +/- keys until the desired
value appears in the display.
Select Enter to save selection.