Descriptionofloadreductionunderdi󰘯erentinputvoltagecondi-Descriptionofloadreductionunderdi󰘯erentinputvoltagecondi-
tionstions
Theinverterwilloutputdi󰘯erentloadreductionunderdi󰘯erentinputvoltages.Whenthe
inputvoltageis500V–850V,theinvertercanensuresu󰘲cientpoweroutput.Withthe
higher input voltage, the power will gradually decrease to ensure the long-term reliable
operation of the machine. It is recommended that the user input the rated voltage at
625 V and the open circuit voltage at 890 V to make the inverter output with the best
e󰘲ciencyandobtainthebestpowergeneration.
SOFAR 110KTLX-G4 DC voltage dependent output power derating curve (Pf=1)
SOFAR 125KTLX-G4 DC voltage dependent output power derating curve (Pf=1)
Installation and User Manual 73/78