Ac output hardware
overflows
Please check whether the inverter is
operating under overload.
Internal temperature is
too high.
Make sure the inverter is installed
where there is no direct sunlight.
Please ensure that the inverter is
installed in a cool/well ventilated
place.
Ensure the inverter is installed
vertically and the ambient temperature
is below the inverter temperature
limit.
Please make sure the grid frequency
and voltage is within the acceptable
range.
Battery low voltage
protection
Please check whether the battery
voltage of the inverter is too low.
Battery low voltage
shutdown
Output hardware
overcurrent permanent
failure
Internal faults of inverter, switch OFF
inverter, wait for 5 minutes, then
switch ON inverter. Check whether the
problem is solved.
If no, please contact technical support.
Permanent Bus
overvoltage failure
Permanent Bus
hardware overvoltage
failure
PV uneven flow
permanent failure
Permanent battery
overcurrent failure in
EPS mode
Output transient
overcurrent permanent
failure