57
en
Parameter Unit Italy France Belgium Czech
Republic
DK 5940
CEI 0-21:
<=3kW
CEI 0-21: >
3kW – 6kW
Restart delay s0 0 0 0 0 0
Mains check On/Off Off On On On On On
- Vac MC max V 280 253 253 253 253 253
- Vac MC min V 161 196 196 184 196 207
- f MC max Hz 54.5 50.1 50.1 50.2 50.05 50.2
- f MC min Hz 45.5 49.9 49.9 47.5 47.5 49.8
- t MC monitoring s 0 300 300 30 60 30
Island Detection On/Off On Off Off On On On
Pac progression %/min Off 20 20 Off 10 Off
P(f)-Mode 2/3/Off Off 3 3 Off 2 Off
- f start Hz 50.2 50.3 50.3 50.2 50.2 50.2
- Reduction %/Hz 40 83 83 40 40 40
- Re-increase %/min105 5101010
Q-Mode Off Off
cosφ(Pac)
Off Off Off
- Vac Lock On/Off Off Off On Off Off Off
- Vac Lock-In V 253 253 242 253 253 253
- Vac Lock-Out V 207 230 230 207 207 207
S max SM2000S VA 1980 1980 1980 1980 1980 1980
S max SM3000S VA 2750 2750 2750 2750 2750 2750
S max SM4200S VA 4180 - 4180 4180 4180 4180
S max SM6000S VA 5060 - 5060 5060 5000 5060
Pac max SM2000S W 1980 1980 1980 1980 1980 1980
Pac max SM3000S W 2750 2750 2750 2750 2750 2750
Pac max SM4200S W 4180 - 4180 4180 4180 4180
Pac max SM6000S W 5060 - 5060 5060 5000 5060
Iac max SM2000S A121212121212
Iac max SM3000S A121212121212
Iac max SM4200S A19-19191919
Iac max SM6000S A 22 - 22 22 22 22
Parameter Unit Greece Greek
Islands
Portugal Great Britain
G83/1-1 G83/2 G59/2
Vac min 1 V 184 184 196 211 200 212
t Vac min 1 ms 500 500 1500 5000 3000 2500
Vac max 1 V 264 264 264 259 262 259
t Vac max 1 ms 500 500 200 5000 1500 1000
Vac min 2 V Off Off Off Off 184 196
t Vac min 2 ms00001000500
Vac max 2 V Off Off Off Off 274 271
t Vac max 2 ms00001000500
Vac 10min max V 253 253 253 Off Off Off
f min 1 Hz 49.5 47.5 47 47 47.5 47.5
t f min 1 ms 500 500 500 5000 20500 20500
f max 1 Hz 50.5 51 51 50.5 51.5 51.5
t f max 1 ms 500 500 500 5000 90500 90500
f min 2 Hz Off Off Off Off 47 47
t f min 2 ms00001000500
f max 2 Hz Off Off Off Off 52 52
t f max 2 ms00001000500