EasyManuals Logo

SolaX Power T-BAT Series User Manual

SolaX Power T-BAT Series
22 pages
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #22 background imageLoading...
Page #22 background image
38
7 Decommissioning
7.1 Dismantling the Battery
Shutting down T-BAT system
Disconnect the cables between BMS and inverter
Disconnect the short-circuit plug on the last battery module
Disconnect the cables.
7.2 Packing
Please pack the BMS and battery modules with the original packaging.
If it is no longer available, you can also use an equivalent carton that meets the
following requirements:
Ÿ Suitable for loads more than 70kg
Ÿ With handle
Ÿ Can be fully closed
7. Decommissioning
7. Decommissioning
8 Maintenance and Warranty
8.1 Maintenance
If the ambient temperature for storage is -20~55°C, recharge the batteries
at least one time every 3 months.
If the ambient temperature for storage is -20~20°C, recharge the batteries
at least one time every 6 months.
8.2 Warranty
SolaX protects this product under warranty when it is installed and used as listed
in this manual. Violation of installation procedure or use of the product in any
way not described in this manual will immediately void all warranties on the
product.
SolaX does not provide warranty coverage or assume any liability for direct
or indirect damages or defects that result from the following causes:
Force majeure (ooding, lightning strike, overvoltage, re,
thunderstorm, ooding etc.)
Improper or noncompliant use
Improper installation, commissioning, start up or operation (contrary to the
guidance detailed in the installation manual supplied with each product)
Inadequate ventilation and circulation resulting in minimized cooling and
natural air ow
Installation in a corrosive environment
Damage during transportation
Unauthorized repair attempts
Failure to adequately maintain the equipment. An on-site inspection by a
qualied technician is possible following 60 months of continuous use.
Warranty claims made beyond 60 months from date of commissioning may
be declined if it cannot be demonstrated that the equipment has been
adequately maintained
External inuence including unusual physical or electrical stress (power failure
surges, inrush current, etc.)
Use of an incompatible inverter or devices
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
39

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolaX Power T-BAT Series and is the answer not in the manual?

SolaX Power T-BAT Series Specifications

General IconGeneral
BrandSolaX Power
ModelT-BAT Series
CategoryCamera Accessories
LanguageEnglish

Related product manuals