>OverVoltage_L1
0.0V
Grid Parameters
>UnderVoltage_L1
0.0V
>OverFreq_L1
0.0Hz
>UnderFreq_L1
0.0Hz
Grid Parameters
Grid Parameters
Grid Parameters
b) Grid Parameters
Here you can set the protection value of grid voltage and frequency.
The default value is the specified value under the current safety
regulations, and the user cannot change it .
The display content will be displayed according to the requirements
of local laws and regulations, which are constantly increasing. Please
refer to the contents displayed on the inverter screen.
Setting
Setting
User value:
0W
Export Control
f) Meter/CT Setting
Battery Type:
Lithium
Max Charge
Current 25A
Charger
Charger
d) PV Connection
PV Mode:
PV Connection
COMM
PV Mode:
PV Connection
MULTI
PV connection is divided into Comm Mode and Multi Mode. Comm Mode
refers to connect a string of PVs to the two MPPT's in an inverter. Multi
Mode refers to the inverter's two MPPT are independent of each other.
The user needs to select the CT or electricity meter to connect the
inverter here. Select the address of the meter. CT does not need to select
the address. In the Meter/CT Settings box, there are two options
(Negative and Positive) available for users. If the Meter is reversely
connected, please click the Negative tab.
c) Charger
Here the user can set the parameters of “Charger on this page, the
inverter is compatible with both lithium battery and lead-acid battery.
The default battery type is lithium, users can change it to lead-acid in
actual usage. The relevant parameters needed to be set.
For the detailed parameters, please refer to the contents display on the
screen.
Max Discharge
Current 25A
Charger
e) Export Control
This feature allows the inverter to control the amount of electricity output
to the grid.
The factory value is the default and can be changed by the user. The user
value set by setup must be less than the maximum. If the user does not
want to supply power to the grid, set it to 0.
When Safety codes related to Australia are chosen, this item won’t show
on the screen.
Select
Meter
CT/Meter Setting
Meter 1Addr:
xxxxxxxx
CT/Meter Setting