Troubleshooting
If the information panel of your inverter does not show the Fault light, check
the following list to make sure that the present state of the installation allows
proper operation of the unit.
— Is the inverter located in a clean, dry, adequately ventilated place?
— Have the DC input breakers been opened?
— Are the specification and length of the cables suitable?
— Are the input and output connections and wiring in good condition?
— Are the configuration settings correct for your particular installation?
— Are the display panel and the communications cable properly
connected and undamaged?
8.2 Routine Maintenance
Contact our Customer Service for further assistance. Please be prepared to
describe details of your system installation and provide model and serial number
of the unit.
Safety checks
Safety checks should be performed at least every 12 months by manufacturer's
qualified person who has adequate training, knowledge, and practical
experience to perform these tests. The data should be recorded in an
equipment log. If the device is not functioning properly or fails any of test, the
device has to be repaired. For safety check details, refer to this manual, section 2
Safety instruction and EC Directives.
Maintain periodically
Only qualified personnel may perform the following works.
During the process of using the inverter, the manage person shall examine and
maintain the machine regularly. The concrete operations are as follows.
1: Check that if the cooling fins on the rear of the inverter are covered by dirt,
and the machine should be cleaned and absorbed dust when necessary. This
work shall be performed from time to time.
2: Check that if the indicators of the inverter are in normal state, check if the
keys of the inverter are in normal state, check if the display of the inverter is
normal. This check should be performed at least every 6 months.
3: Check that if the input and output wires are damaged or aged. This check
should be performed at least every 6 months.
4: Clean the inverter panels and check their security. This should be carried out
at least every 6 months.
Regular safety check and maintenance are required.
72 73
Decommissioning
9 Decommissioning
9.1 Dismantling the Inverter
Disconnect the inverter from DC Input and AC output.
Wait for at least 5 minutes for de-energizing.
Disconnect communication and optional connection wirings.
Remove the inverter from the bracket.
Remove the bracket if necessary.
If possible, please pack the inverter with the original packaging.
If it is no longer available, you can also use an equivalent carton that
meets the following requirements.
Suitable for loads more than 30 kg.
With handle.
Can be fully closed.
Store the inverter in dry place where ambient temperatures are always
between -30°C - +60°C. Take care of the inverter during the storage and
transportation, keep less than 4 cartons in one stack.
9.2 Packaging
When the inverter or other related components need to be disposed, have
it carried out according to local waste handling regulations. Please be sure
to deliver wasted inverters and packing materials to certain site where can
assist relevant department to dispose and recycle.
9.4 Waste Disposal
9.3 Storage and Transportation

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Solax X3-PRO G2 Series and is the answer not in the manual?

Solax X3-PRO G2 Series Specifications

General IconGeneral
ModelX3-PRO G2 Series
CategoryInverter
MPPT Efficiency99.9%
Max. DC Voltage1100V
THDi<3%
DC SwitchYes
European Efficiency98%
CommunicationWiFi, Ethernet, RS485
Operating Temperature Range-25°C to +60°C
AC Voltage Range310V-480V
AC Grid Frequency50/60 Hz
Warranty10 years
Rated Power6kW, 8kW, 10kW, 12kW, 15kW, 20kW, 25kW, 30kW
Number of MPPTs2 or 4 (depends on model)
AC Output Power6kW / 8kW / 10kW / 12kW / 15kW / 20kW / 25kW / 30kW
Nominal AC Voltage400V
ProtectionDC Reverse Polarity Protection, AC Short Circuit Protection, Output Over Current Protection, Output Over Voltage Protection