Solax X3-PRO G2 Series - Technical Data; DC Input Specifications; AC Output Specifications

Solax X3-PRO G2 Series
41 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
X3-PRO-10K-G2-LV
Model
X3-PRO-12K-G2-LV
X3-PRO-15K-G2-LV
4.2 AC Output
15000
16500
22.8, 21.8
24.2
Model
20000
22000
30.3, 29.0
33.6
X3-PRO-15K-G2(3D) X3-PRO-25K-G2(3D) X3-PRO-20K-G2(3D)
25000
27500
37.9, 36.3
41.8
30000
30000
45.5, 43.5
45.5
X3-PRO-30K-G2(3D)
50/60
17000
18700
25.8, 24.7
27.5
X3-PRO-17K-G2(3D)
15000
16500
39.4
43.4
Model
X3-PRO-15K-G2-LV
50/60
3~/N/PE, 127/220; 3~/PE, 220
X3-PRO-10K-G2-LV X3-PRO-12K-G2-LV
Technical Data
15000
800
360
160-650
0 553 0- 0
32/32
40/40
200
2
A:2/B:2
18000
8 00
360
160-650
300-550
/32 32
/40 40
200
2
A:2/B:2
22500
8 00
360
160-650
300-550
/32 32
/40 40
200
2
A:2/B:2
12000
13200
31.5
34.7
10000
11000
26.3
28.9
14 15
0
Yes
10000 12000 15000
Max. MPPT power limit per MPPT”means the maximum PV production when using one of the
MPPTs only.
Technical Data
Max. inverter backfeed current to
the array [ A]d.c.
Max. recommended DC power [W]
Max. PV voltage [d.c. V]
Rated input voltage [d.c. V]
MPPT voltage range [d.c. V]
Max. PV current [d.c. ] A
Isc PV array short circuit
current [d.c. ] A
Start input voltage [d.c. V]
No. of MPPT
Strings per MPPT
DC disconnection switch
Max. MPPT power limit
per MPPT [W]
MPPT voltage range
@ full load [d.c. V]
8000
8800
12.2, 11.6
13.2
Model
10000
11000
15.2, 14.5
16.0
0.8 leading-0.8 lagging
Three-phase
50/60
12000
13200
18.2, 17.4
19.3
15000
16500
22.8, 21.8
24.2
17000
18700
25.8, 24.7
27.5
20000
22000
30.3, 29.0
33.6
3~/N/PE, 220/380, 230/400; 3~/PE, 380, 400
X3-PRO-8K-G2(2D) X3-PRO-10K-G2(2D) X3-PRO-15K-G2(2D) X3-PRO-12K-G2(2D) X3-PRO-17K-G2(2D) X3-PRO-20K-G2(2D)
Rated output apparent power [VA]
Max. output apparent power [VA]
Nominal AC voltage [a.c. V]
Nominal AC frequency [Hz]
Rated output current [a.c. A]
Max. output continuous
current [a.c. A]
THDi
Power factor range
Feed-in phase
<3%
Current (inrush) [a.c. A]
Maximum output fault
current [a.c. A]
Maximum output overcurrent
protection [a.c. A]
60 (18 μs)
100
89
0.8 leading-0.8 lagging
Three-phase
THDi
Power factor range
Feed-in phase
<3%
Current (inrush) [a.c. A]
Maximum output fault
current [a.c. A]
Maximum output overcurrent
protection [a.c. A]
60 (18 μs)
100
89
Rated output apparent power [VA]
Max. output apparent power [VA]
Nominal AC voltage [a.c. V]
Nominal AC frequency [Hz]
Rated output current [a.c. A]
Max. output continuous
current [a.c. A]
3~/N/PE, 220/380, 230/400; 3~/PE, 380, 400
Rated output apparent power [VA]
Max. output apparent power [VA]
Nominal AC voltage [a.c. V]
Nominal AC frequency [Hz]
Rated output current [a.c. A]
Max. output continuous
current [a.c. A]
0.8 leading-0.8 lagging
Three-phase
THDi
Power factor range
Feed-in phase
<3%
Current (inrush) [a.c. A]
Maximum output fault
current [a.c. A]
Maximum output overcurrent
protection [a.c. A]
60 (18 μs)
100
89
* If there are two data for this parameter, each data corresponds to the corresponding voltage.
*
*