Operation Method Operation Method
7.2 LCD Function & Operation
Power 0W
Normal
Today 0.0kWh
Normal
>Status
>Grid 0.0V
>Language
>Settings
>Error Logs
>About
Master:
x.xx
Manager:
x.xx
0 0 0 0
1:xxYxxxDxxH
Error1
>Safety
Export Control
Enter
Total 0.0kWh
Normal
Back
Product SN:
Up
Down
Back
**Go to next page
**
>Ua 0.0V
Down
Up
*
*User can also see
the U, I & P of the PV.
(U1,I1,P1,U2,I2,P2)
Back
Back
Up
Down
Up
Down
Up
Down
Up
Down
Up
Down
Up
Down
Down
Enter
Enter
Enter
Enter
Back
Enter
Back
Enter
Back
Up
Down
Enter
Back
***Only six latest
level 1 level 2 level 3
***
>Meter Energy
Today Import:
0.0kWh
Up
Down
Enter
Back
Internal Code:
A:x.xx D:x.xx
Up
Down
Pgrid 0W
Normal
Up
Down
Enter
>DateTime
Up
Down
Total Import:
0.0kWh
Today Export:
0.0kWh
Total Export:
0.0kWh
Up
Down
Up
Down
Up
Down
>Solar 0.0V
Up
Down
>2021-01-01
00:00
Enter
Back
>U1 0.0V
Down
Up
*
......
..................
errors were kept
>English
German
......
XXX XXXXXXXXXXX
*User can see the U, I
& F of the grid.
(Ua,Ia,Fa,Ub,Ib,Fb,Uc
,Ic,Fc,Pout,Pgrid)
>Export Control
>DRM Function
>Grid Services
>Grid Protection
>VDE4105<
>P(freq)
>Mode Select
>Meter/Disable<
Enter
Enter
Enter
>Mode Select
>Enable<
Enter
Back
Back
Back
Back
Back
Up Down
Up Down
Up Down
Up
Down
0.0
> O/V Stage1
**Go to next page
**Go to next page
**
**
>User Value
30000W
Enter
Back
>New Password
Up Down
>RS485 CommAddr
Up Down
>MpptScanMode
Up
Down
>Reset Energy
>Reset Meter
>Reset Errorlogs
Settings page
**
>Safety
>Country
Enter
Up
Down
**
**Go to next page
**
**Go to next page
Up
Down
Up
Down
>Reset WiFi
Up
Down
Up
Down
Enter
Back
YES/NO
> Reset
Enter
Back
YES/NO
> Reset
Enter
Back
YES/NO
> Reset
Enter
Back
YES/NO
> Reset
>Machine type
Up
Down
Machine type
15.0T
Enter
Back
>ParallelSetting
Up Down
**
**Go to next page
54 55

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Solax X3-PRO G2 Series and is the answer not in the manual?

Solax X3-PRO G2 Series Specifications

General IconGeneral
ModelX3-PRO G2 Series
CategoryInverter
MPPT Efficiency99.9%
Max. DC Voltage1100V
THDi<3%
DC SwitchYes
European Efficiency98%
CommunicationWiFi, Ethernet, RS485
Operating Temperature Range-25°C to +60°C
AC Voltage Range310V-480V
AC Grid Frequency50/60 Hz
Warranty10 years
Rated Power6kW, 8kW, 10kW, 12kW, 15kW, 20kW, 25kW, 30kW
Number of MPPTs2 or 4 (depends on model)
AC Output Power6kW / 8kW / 10kW / 12kW / 15kW / 20kW / 25kW / 30kW
Nominal AC Voltage400V
ProtectionDC Reverse Polarity Protection, AC Short Circuit Protection, Output Over Current Protection, Output Over Voltage Protection