18 • Technical Data
_____________________________________________________________________________________________
3.6 Ordering Information
RVS-DN 31- 400- 230 230- 0- S
Full load Current Mains Voltage Control Supply
Voltage
Control Input
Voltage
Options Front Panel
Full load Current
Specify Description
RVS-DN’s
FLC [A]
8, 17, 31, 44, 58, 72, 85
(2)
, 105
(2)
, 145
(2)
, 170
(2)
, 210, 310, 390, 460, 580, 820, 950
(1)
, 1100
(1)
,
1400
(1)
, 1800
(1)
, 2150
(1)
, 2400
(1)
, 2700
(1)
, 3000
(1)
.
Mains Voltage
Specify Description
400 230 – 400 VAC, +10% -15%, 50/60Hz
480 480 VAC, +10% -15%, 50/60Hz
600 600 VAC, +10% -15%, 50/60Hz
690 690 VAC, +10% -15%, 50/60Hz
1000
(1)
1000 VAC +10% -15%, 50/60Hz; Models: 105A, 170A, 210A, 310A, 390A, 460A.
1200
(1)
1200 VAC +10% -15%, 50/60Hz; Models: 170A, 210A, 310A, 390A, 460A.
Control Supply Voltage (Terminals 1 and 3)
Specify Description
115 115 VAC, 50/60Hz, +10% -15%
230 230 VAC, 50/60Hz, +10% -15%
110VDC 110 VDC, +10% -15%
Control Input Voltage (Terminals 4 to 9)
Specify Description
115 or
230
90-230 VAC, 50/60Hz, +10%
24 24V AC/DC, +10% -15%
48 48V AC/DC, +10% -15%
Options
Specify Description
0 No options
3M Communication - RS-485 (Modbus)
(3) (5)
3P Communication - Profibus
(3)
(Must be factory supplied).
4 Insulation tester
(4) (5)
5 Analog card – Thermistor in and Analog out
(4) (5)
8 Harsh environment treatment. (Must be factory supplied).
9 Preparation for Bypass contactor
(1) (2)
B Line and load bus bars at bottom (Applicable in Marine/UL models 210-820A)
D Remote panel mounting replacing the original panel.( supplied with 1.5 m cable)
H Special character set LCD display
M Marine approval (consult factory)
U UL & cUL approval (8-820A models only and up to 600V)
T Tachometer card for special drive systems (consult factory)
(4)
(5)
ROC Chinese display
Front Panel
Specify Description
S Standard
RU Russian front panel and Russian characters LCD display.
Notes:
(1) RVS-DN 950-3000A, RVS-DN 1000V and RVS-DN 1200V must be operated with a bypass contactor. For
usage without bypass contactor consult the factory.
(2) Preparation for bypass contactor is standard in RVS-DN 85-170A.
(3) Only one option, either 3M or 3P may be installed in one RVS-DN.
(4) Only one option, either 4 or 5 or T may be installed in one RVS-DN.
(5) All options must be factory installed in RVS-DN 8-72A.
(6) Current transformers (CTs) for RVS-DN950A and up are designed to allow installation within 1.5m from
the RVS-DN (use the CTs for the RVS-DN only!)
(7) If you need more than one option, make sure to indicate it with a plus sign (+), for example 8+9 for Harsh
environment and preparation for bypass contactor.
Ordering Example:
RVS-DN rated 820A, mains voltage - 230V, Control Supply voltage - 115V, Control Input
- 115V Modbus communication card, Analog card, Harsh environment treatment, preparation for bypass and
standard front panel:
RVS-DN 820 - 400 - 115 – 115 - 3M + 5+ 8 + 9 – S