THERMOCUBE II 200-650W THERMOELECTRIC CHILLER MANUAL 52-14790-1
SOLID STATE COOLING SYSTEMS, 167 MYERS CORNERS ROAD, WAPPINGERS FALLS, NY 12590 46
TELEPHONE: (845) 296-1300, FAX: (845) 296-1303, WEB: WWW.SSCOOLING.COM VERSION M2
Persistence and Degradability Persistence is unlikely
Bioaccumulation/ Accumulation No information available.
Mobility Will likely be mobile in the environment due to its water solubility.
Component
log Pow
Ethylene glycol
-1.93
13. Disposal considerations
Waste Disposal Methods Chemical waste generators must determine whether a discarded chemical
is classified as a hazardous waste. Chemical waste generators must also
consult local, regional, and national hazardous waste regulations to ensure
complete and accurate classification.
14. Transport information
DOT Not regulated
TDG Not regulated
IATA Not regulated
IMDG/IMO Not regulated
15. Regulatory information
All of the components in the product are on the following Inventory lists: X = listed
International Inventories
Component
TSCA
DSL
NDSL
EINECS
ELINCS
NLP
PICCS
ENCS
AICS
IECSC
KECL
Ethylene glycol
X
X
-
203-473-3
-
X
X
X
X
X
Legend:
X - Listed
E - Indicates a substance that is the subject of a Section 5(e) Consent order under TSCA.
F - Indicates a substance that is the subject of a Section 5(f) Rule under TSCA.
N - Indicates a polymeric substance containing no free-radical initiator in its inventory name but is
considered to cover the designated polymer made with any free-radical initiator regardless of the amount
used.
P - Indicates a commenced PMN substance
R - Indicates a substance that is the subject of a Section 6 risk management rule under TSCA.
S - Indicates a substance that is identified in a proposed or final Significant New Use Rule
T - Indicates a substance that is the subject of a Section 4 test rule under TSCA.
XU - Indicates a substance exempt from reporting under the Inventory Update Rule, i.e. Partial Updating of
the TSCA Inventory Data Base Production and Site Reports (40 CFR 710(B).
Y1 - Indicates an exempt polymer that has a number-average molecular weight of 1,000 or greater.
Y2 - Indicates an exempt polymer that is a polyester and is made only from reactants included in a specified
list of low concern reactants that comprises one of the eligibility criteria for the exemption rule.
U.S. Federal Regulations
TSCA 12(b) Not applicable
SARA 313
Component
CAS-No
Weight %
SARA 313 Threshold
Values %
Ethylene glycol
107-21-1
>95
1.0
SARA 311/312 Hazard Categories See section 2 for more information