Max. DC input voltage (Volts)
MPPT voltage range (Volts)
Max. input current (Amps)
MPPT number/Max input strings number
Rated grid voltage (Volts)
Rated output current (Amps)
Power Factor (at rated output power)
Operating frequency range (Hertz)
Max.efficiency
EU efficiency
Model
Dimensions
Weight
1100
2/2
50/60
98.3%
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
600
4000
4400
4400
6.1/5.8
THDi (at rated output power)
Start-up voltage (Volts)
180
Max short circuit input current (Amps)
Rated DC voltage (Volts)
Rated grid frequency (Hertz)
310W*563H*219D (mm)
17.8kg
3/N/PE~220/380, 230/400
45...55 or 55...65
Max. DC input voltage (Volts)
MPPT voltage range (Volts)
Max. input current (Amps)
MPPT number/Max input strings number
Rated grid voltage (Volts)
Rated output current (Amps)
Max. output current (Amps)
Power Factor (at rated output power)
Operating frequency range (Hertz)
Max.efficiency
EU efficiency
Model
Dimensions
Weight
Topology
Operating ambient temperature range
Ingress protection
Noise emission (typical)
Cooling concept
Max.operation altitude
Grid connection standard
310W*563H*219D (mm)
1100
16+16
20+20
2/2
50/60
98.3%
97.7%
17.8kg
Transformerless
IP66
<30 dBA
Natural convection
4000m
Display
Communication connections
Warranty Terms
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
LCD, 2×20 Z.
RS485, DO, DI, Optional: Wi-Fi, GPRS,USB*
5 Years (Extend to 20 Years)
G98 or G99, VDE-AR-N 4105 / VDE V 0124,
EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019,
RD 1699 / RD 244 / UNE 206006 / UNE 206007-1,
CEI 0-21, C10/11, NRS 097-2-1, TOR,
EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068,
IEC 61683, EN 50530
600
3000
3300
3300
4.6/4.3
4.7
S5-GR3P3K
THDi (at rated output power)
<2%
160...1000
Start-up voltage (Volts)
180
Max short circuit input current (Amps)
Rated DC voltage (Volts)
Rated grid frequency (Hertz)
10. Specifications10. Specifications
.46..47.
>0.99 (0.8 leading - 0.8 lagging)
Self consumption (night)
<1 W
-25℃...+60℃
Safety/EMC standard
IEC 62109-1/-2, EN 61000-6-1/-2/-3/-4
DC connection
AC connection
MC4 connector
Quick connection plug
3/N/PE~220/380, 230/400
Max. output current (Amps)
6.4
45...55 or 55...65
>0.99 (0.8 leading - 0.8 lagging)
Topology
Operating ambient temperature range
Ingress protection
Noise emission (typical)
Cooling concept
Max.operation altitude
Transformerless
<30 dBA
Natural convection
Self consumption (night)
-25℃...+60℃
0~100%
Relative humidityRelative humidity
0~100%
16+16
20+20
<1 W
97.7%
Grid connection standard
Display
Communication connections
Warranty Terms
LCD, 2×20 Z.
5 Years (Extend to 20 Years)
G98 or G99, VDE-AR-N 4105 / VDE V 0124,
EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019,
RD 1699 / RD 244 / UNE 206006 / UNE 206007-1,
CEI 0-21, C10/11, NRS 097-2-1, TOR,
EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068,
IEC 61683, EN 50530
Safety/EMC standard
IEC 62109-1/-2, EN 61000-6-1/-2/-3/-4
DC connection
AC connection
MC4 connector
Quick connection plug
<2%
160...1000
Optional USB* :only for the brazilian market
S5-GR3P4K
RS485, DO, DI, Optional: Wi-Fi, GPRS,USB*
IP66
4000m
Optional USB* :only for the brazilian market