.9..8.
To select a location for the inverter, the following criteria should be considered:
Do not install in small closed spaces where air cannot circulate freely. To avoid
overheating, always make sure the flow of air around the inverter is not blocked.
Exposure to direct sunlight will increase the operational temperature of the inverter and
may cause output power limiting. Ginlong recommends inverter installed to avoid
direct sunlight or raining.
To avoid over heating ambient air temperature must be considered when choosing
the inverter installation location. Ginlong recommends using a sun shade minimizing
direct sunlight when the ambient air temperature around the unit exceeds 104°F/40°C.
5.1 Select a Location for the Inverter
5. Installation
Figure 5.1 Recommended Installation locations
4. Product handing and storage
4.2 Product Storage
Storage temperature must be between -40 and 70 and the humidity should be
between 0 and 95% non-condensing.
Stacknomorethanthree(3)invertershigh.
If the inverter is not to be installed immediately, storage instructions and environmental
conditions are below:
Use the original box to repackage the inverter, seal with adhesive tape with the
desiccant inside the box.
Store the inverter(s) in a clean and dry place, free of dust and dirt.
Keep box(es) away from corrosive materials to avoid damage to the inverter enclosure.
Inspect packaging regularly. If packaging is damaged(wet, pest damage, etc),
repackage the inverter immediately.
Store the inverter(s) on a flat, hard surface - not inclined or upside down.
After long-term storage, the inverter needs to be fully examined and tested by qualied
service or technical personnel before using.
Restarting after a long period of non-use requires the equipment to be inspected
and, in some cases, the removal of oxidation and dust that has settled inside the
equipment will be required.
NOTE:
Nothing should be stored on or placed against the inverter.
WARNING: Risk of fire
Despite careful construction, electrical devices can cause fires.
Do not install the inverter in areas containing highly flammable materials or
gases.
Do not install the inverter in potentially explosive atmospheres.
The mounting structure where the inverter is installed must be fireproof.

Other manuals for SOLIS S5 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SOLIS S5 Series and is the answer not in the manual?

SOLIS S5 Series Specifications

General IconGeneral
Number of MPPTs2
Output Voltage230 V
Frequency50/60 Hz
Max. AC Output Power5000W
Operating Temperature Range-25°C to +60°C
Rated AC Output Power2.5 kW / 3 kW / 3.6 kW / 4 kW / 5 kW / 6 kW
Max. AC Output Current21.7A
Cooling MethodNatural Convection
Humidity0~100 %
ModelS5 Series