FCAx3 USER MANUAL
sollateksupport@sollatek.com 11
A3+ CMYK
3.3 ENERGY SAVING MODE
The FCAx3 has an Energy Saving mode that provides reduced compressor operation when the outlet is closed and no
customer demand by setting the cut-in and cut-out temperatures higher than in normal mode. When the FCAx3 does not
sense a door opening for the pre-set duration, then the FCAx3 will enter Energy Saving Mode and run using the energy-saving
cut-in and cut-out temperature. When the door is opened or the maximum energy-saving timer has elapsed, the FCAx3 will
resume normal operation.
CUT IN
CUT OUT
Eco Mode
Temperature
Time
Engery Saving Max Duration
OPEN
CLOSE
Door Switch
Energy Saving Mode
Door Close Duration
to Start Energy Saving
Door Open Duration to Exit Engery Saving
Energy Saving is activated
Energy Saving is terminated
CUT IN
CUT OUT
ON
OFF
Compressor
Normal Mode
Temperature