11. SPECIFICATION
REFRIGERATION CONTROL
Temperature Control Method Air or evaporator
Temperature Control Range -40 to +45°C (-40 to +113°F)
Temperature Time Delay 1 to 125 s
Defrost control Timed,Active or Manual
Advanced Defrost Mode Pre/Post Derost, Emergency Defrost
Energy Saving Temperature Set-back, Fan Cycling
Input Type Temperature Sensor & Door Switch
Temperature Probe Type 100 KΩ NTC (β
25/50
: 3990 k)
Output control Compressor, Lights, Evaporator Fan, Reverse Fan, or Heater
Relays
FCA13
Compressor Only
FCA22
Compressor + Aux1
FCA32
Compressor + Aux1 + Aux2
Output Relay Ratings UL 60730 IEC 60730
Compressor Relay Motor Load 75-240 Vac 10 FLA 60 LRA 30k cycles
Motor Load 75-120 Vac 12 FLA 72 LRA 30k cycles
16 A, 250 V
Aux1 (Relay #2) Motor Load 75-240 Vac 1.5 FLA 9LRA 30k cycles 5 A, 250 V
Aux2 (Relay #3) Resistive Load 75-240 Vac 5A, 50k cycles 5 A, 250 V
Intelligent Time Delay 0 to 600 s
Refrigerant Compatibility CO
2
& Hydrocarbon
BLUETOOTH & BATTERY
Type/version BLE 4.1
RF Power Output -20 dBm to +4 dBm
Frequency 2.4 GHz ISM
Connectivity Eddystone, iBeacon & connection to the Sollatek Smart Device Application
Bluetooth Standard IEEE 802.15.1
Battery Type Rechargeable Lithium polymer
Nominal Voltage 3 V
Capacity 5.5 mAh
Typical Run Time From a Single Charge RTC Only: Approx. 15 days
RTC + BLE Advertising: Approx. 10 days
Memory Size Internal memory for storage of approximately 11,000 events
USER INTERFACE
Temperature Control Dial OFF, 1 to 9
LEDs 3 x LEDs (Red, Yellow, Green)
POWER & VOLTAGE PROTECTION
Operating Voltage Range 75 to 240 V
Withstand Voltage Up to 450 V
Working Frequency Auto-sense 50/60 Hz
Type of Protection High / Low voltage, Spike / Surge & Frequency
High / Low Voltage Blind time 0 to 25 s
Rated Impulse Voltage 2.5 kV
Over voltage category Category II
CONNECTOR / INTERFACE
Input Connector 3 pairs of 0.11” (2.80 mm) Fast-On
Output connector Up to 5 x 0.25” (6.35 mm) Fast-On (depending on model)