28
HCD-SC5/SC6/SC8
5. VERSION INFORMATION
On the Test Mode Menu screen, selecting [6] displays the ROM
version and region code.
The parenthesized hexadecimal number in version field is checksum
value of ROM.
## Version Information ##
IF con. Ver.x. xx
SYScon. Ver.x. xx (xxxx)
Model DAV-SCX
Region 0x
Config xxxxxxxx
Front End Ver.x.xx
Exit: RETURN
IF con. : The version of system controller (IC901).
SYScon. : The version of DVD system processor (IC206).
Front End: The version of mechanism controller (IC301).
6. VIDEO LEVEL ADJUSTMENT
On the Test Mode Menu screen, selecting [7] displays color bars
for video level adjustment. During display of color bars, OSD
disappears but the menu screen will be restored if pressing the
[RETURN] key.
4. MECHA ERROR HISTORY
On the Test Mode Menu screen, selecting [5] displays the information
of mechanism deck error history.
The history information from last 1 up to 8 can be scrolled with the
O
key or
o
key. Also, specific information can be displayed by
directly entering that number with ten keys.
### Mecha Error History ###
1. aa bb cc dd xx xx xx xx
2. aa bb cc dd xx xx xx xx
3. aa bb cc dd xx xx xx xx
4. aa bb cc dd xx xx xx xx
5. aa bb cc dd xx xx xx xx
6. aa bb cc dd xx xx xx xx
7. aa bb cc dd xx xx xx xx
8. aa bb cc dd xx xx xx xx
Scroll:UP/DOWN
(1.Latest Err.) Exit: RETURN
aa : The error in the midst of initializing the mechanism deck.
bb : The error in the midst of loading operation.
cc : The error in the midst of up/down the stocker.
dd : The error in the midst of switching the mechanism deck mode.
xx : Not used.
Error code (aa)
FF : Complete the initializing. (normal operation)
11 : Stocker movement (to chucking position) failing in the midst
of initializing the mechanism deck.
12 : Stocker movement (to chucking position) failing in the midst
of initializing the mechanism deck.
1x : Initializing the mechanism deck.
2x : Initializing the mechanism deck.
3x : Initializing the mechanism deck.
41 : Disc eject failing in the midst of initializing the mechanism
deck.
4x : Initializing the mechanism deck.
50 : Disc eject failing in the midst of initializing the mechanism
deck.
5x : Initializing the mechanism deck.
A2 : Disc eject failing in the midst of initializing the mechanism
deck.
Ax : Initializing the mechanism deck.
D3 : Disc eject failing in the midst of initializing the mechanism
deck.
Dx : Initializing the mechanism deck.
Ex : Initializing the mechanism deck.
Error code (bb)
00 : Initializing the mechanism deck.
10 : Retry over of eject and loading.
30 : Open operation in no disc status.
60 : Retry over of eject and loading.
70 : Disc is chucking position.
81 : Retry failed of disc movement from chucking position to
stocker.
83 : Retry preparation failed of disc movement from chucking
position to stocker.
90 : Disc is stored in the stocker.
A1 : Retry failed of disc movement from stocker to chucking
position.
A3 : Retry preparation failed of disc movement from stocker to
chucking position.
B0 : Just before the release operation.
B1 : Retry failed of the release operation.
Error code (cc)
10 : Under a stop.
22 : Retry preparation failed.
23 : Retry failed.
Error code (dd)
10 : Under a stop.
22 : Retry preparation failed.
23 : Retry failed.

Table of Contents