EasyManua.ls Logo

Sony HCD-SHAKE5 - TROUBLESHOOTING; Switching Regulator Diagnosis Flow

Sony HCD-SHAKE5
86 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HCD-SHAKE5/SHAKE6D
19
Switching Regulator Diagnosis Flow
The Output from Switching regulator is checked.
Is following power voltage up to standard?
Standby  Demo mode Power On
CN 201 pin1
CN 401 pin9
AC IN
Yes
No
Yes
END
No
Checks whether the state of a Cable and Outlet are normal.
If there are no problems, checks circumference circuit for
Main on/Sub on Output of Main mount side.
Replaces Switching regulator if it is not up to standard.
The Power Control signal to Switching regulator is checked.
Is following power voltage OK?
Main on/Sub on Standby Demo mode Power On
CN 201 :pin7 Low (0V) Hi (3.3V)   Hi (3.3V)
13V±0.5V
13V±0.5V
0V 61V±2.5V
pin6 0V 24V±2.5V
pin4 0V -24V±2.5V
pin1 0V -61V±2.5V
(1) AC input
(2) Fuse
(3) Sub Power transformer
(4) CN 201 Connector
pin1-2: 13V
pin3-4: GND
pin5: AC-DET
pin7: MAIN-ON
(5) MAIN Power transformer
(6) CN 401 Connector
pin1-3: V1- (DC-61V)
pin4: V2- (DC-24V)
pin5: GND
pin6: V2+ (DC+24V)
pin7-9: V1+ (DC+61V)
(2)
(1)
(4)
(6)
(3)
(5)
SECTION 5
TROUBLESHOOTING