EasyManua.ls Logo

Sony MVS-6520 - P-Bus Trigger

Sony MVS-6520
454 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
USO RESTRITO
228
Control of GPI Devices
Chapter
11
External
Devices
not executed; when the [RUN] button is pressed, then the
first keyframe action is executed.
To execute an action when the [REWIND] button is
pressed, it is necessary to set this action (Rewind Action).
To carry out this setting, press [Rewind Action] in the
Device >P-Bus Timeline >P-Bus Timeline menu (5321) to
recall the Rewind Action menu (5321.1). In this setting
screen, use the same setting method as in the screen for
setting an action on the P-Bus timeline.
Alternatively, you can select the reverse arrangement,
whereby when the [REWIND] button is pressed, this
executes the action set for the first keyframe, and when the
[RUN] button is pressed the first keyframe action is not
executed. In this case, the Rewind Action setting is still
valid.
For details,
1
“Setting the First Keyframe When a
Rewind is Executed” (p. 341).
Carrying out a Direct Store
You can carry out a Learn with the register number
specified for the device selected in the menu.
1
In the Device >P-Bus Timeline >P-Bus Timeline
menu (5321), select the device ID.
2
Press [Direct Store].
3
Enter the register number (1 to 250) for which you
want to carry out the Learn.
4
Press [Enter].
P-Bus Trigger
“P-Bus trigger is a function whereby a button operation in
the Flexi Pad outputs an action command to a P-Bus
device.
Notes
To use the P-Bus trigger function, the P-Bus control mode
must be set to [Trigger]. Make this setting in the
Engineering Setup >Panel >Device Interface menu (7325).
For details,
1
“Setting the Control Mode for P-Bus
Devices” (p. 339).
Action command for an operation in the Flexi Pad
RCLL: Recall
STOR: Store
This recalls the register specified in the numeric keypad
control block, and a Recall or Store is carried out,
according to the setting.
RUN: Trigger 1
REWIND: Trigger 4
>> NEXT: Trigger 7
<< PREV: Trigger 8
Outputting an action command
As an example, to output a Recall, use the following
procedure.
1
In the Flexi Pad, press the [EFF] button, turning it on.
2
Select [PBUS] using the region selection buttons.
3
Enter the number of the register (1 to 250) to be
recalled with the numeric keypad buttons.
4
Press the [ENTR] button.
Control of GPI Devices
You can control GPI devices from this system, through the
GPI output port of the switcher or DCU.
Notes
If using a switcher GPI output port, a controllable output
port must be assigned using the control panel.
Make this setting in the Engineering Setup >Panel
>Device Interface >Tally/GPI Output Config menu
(7325.12).
For details,
1
“Assigning a Parallel Output Port”
(p. 339).
GPI timeline
For a keyframe effect controlled from the control panel,
the GPI timeline allows you to set an action (setting a
trigger output from a particular GPI output port) at a
keyframe point on the GPI timeline. At any keyframe
point, you can make a maximum of eight GPI output port
settings.
GPI timeline actions
Switcher GPI output port
DCU GPI output port
The data set in the Device menu are saved in a keyframe
effect register. When you recall this register and start
execution of the keyframe effect, and advance the effect to
the keyframe point for which the GPI output is set, a
trigger pulse is output to the external device from the
specified GPI output port.

Table of Contents

Other manuals for Sony MVS-6520

Related product manuals