EasyManua.ls Logo

Sony MVS-6520 - Making Switcher Processor GPI Output Settings

Sony MVS-6520
454 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
USO RESTRITO
Interfacing with External Devices 361
No.
Parameter
Adjustment
3
Pulse Width
Pulse width
4
Timing
a)
Chapter
19
Switcher
Setup
1
In the Engineering Setup >Switcher >Device Interface
>GPI Input menu (7337.2), select the action to be set,
and press [H/L Set].
The H/L Set menu (7337.3) appears.
2
Select the setting to apply.
3
To apply the selection made in step 2 when the input
is the GPI high level, press [H Set]. To apply the
selection the input is low, press [L Set].
Notes
When “Action” is “Format,” these settings conflict
with the current settings, but after making the
settings, agreement is restored after a pulse change
or power off/on.
When “Action” is “Bkgd A Side Flags” or Bkgd B
Side Flags,” the levels are fixed, as follows.
High level: Off
Low level: On
To set the level for the format converter
1
Set “Action” to Format” in step
5
of the procedure in
“Making Switcher Processor GPI Input Settings”
(
1
p. 360).
The format converter list appears.
2
Select the format converter that you want to set from
the list.
3
In the <FC Input/Output> group, press [H Set] or [L
Set] to set the high level or low level, respectively.
Making Switcher Processor GPI
Output Settings
The switcher port must be assigned before using the
following procedure
(
1
“Assigning a Parallel Output
Port” (p. 339)).
1
In the Engineering Setup >Switcher >Device Interface
menu (7337), press [GPI Output].
The GPI Output menu (7337.4) appears.
2
Select the setting to apply.
3
In the <Trigger Type> group, select the trigger type.
(Rising Edge): The trigger causes the relay
contacts to be open-circuit or drives the output
high, and holds this state for the specified pulse
width.
(Falling Edge): The trigger causes the relay
contacts to be shorted or drives the output low, and
holds this state for the specified pulse width.
(Any Edge): Each time the trigger occurs, the
relay contacts are alternately closed or opened, or
the output is switched between high and low.
Status: Depending on the status, the relay contacts are
closed or opened, or the output is switched
between high and low.
No Operation: The trigger has no effect on the relay
state or output level.
4
Select the pulse width and timing to be set.
Output timing
a)
1: Field 1, 2: Field 2, 3: Any
When is selected as the trigger polarity, there is
no Pulse Width setting. When “Status” is selected,
there is no Pulse Width or Timing setting.
5
In the <Source> group, select the action block.
M/E-1 and P/P: Sets an action for the M/E or PGM/
PST bank.
Common: Sets an action for error status.
6
Select the action to be set.
7
Press [Action Set] to confirm the action selection.
Selectable actions for various trigger types
When the trigger type is other than “Status”
(The x in M/E-x is the M/E bank number, the x in DSKx
is the DSK number, and the x in Keyx is the key
number.)
When Source is M/E-x: Cut, Auto Trans, Keyx Cut,
Keyx Auto Trans, Keyx SS ? Recall, Effect ? Recall,
Effect ? Recall & Run, KF Run, KF Stop, KF
Rewind, No Action
When Source is P/P: Cut, Auto Trans, DSKx Cut, DSKx
Auto Trans, FTB Cut, FTB Auto Trans, DSKx SS ?
Recall, Effect ? Recall, Effect ? Recall & Run, KF
Run, KF Stop, KF Rewind, No Action
When Source is Common: No Action
When the trigger type is “Status”
(The x in M/E-x is the M/E bank number, the x in DSKx
is the DSK number, and the x in Keyx is the key
number.)
When Source is M/E-x: Keyx On, No Action
When Source is P/P: DSKx On, No Action
When Source is Common: Error Make, Error Break, No
Action

Table of Contents