Router Interface Settings 373
No.
Parameter
Adjustment
1
Source
Source start address
Chapter
22
Router
Interface
and
Tally
Setup
Router Interface and
Tally Setup
Chapter
22
Router Interface Settings
In this system, the interface with a router (routing
switcher) uses the S-Bus protocol. It is therefore necessary
to assign inputs and outputs of the switcher and so on to an
S-Bus space.
The settings are common to the parallel and serial tallies.
Assigning Switcher Inputs and
Outputs to S-Bus Space
1
In the <Device> group of the Engineering Setup
>Router/Tally >Router menu (7361), select the device
to which the settings apply.
SWR1: Settings apply to switcher 1.
[SWR2] setting is disabled.
2
In the <Matrix Size> group, select the matrix size.
136 × 138 (Standard): Assigns to S-Bus space with
the switcher input/output at 136 × 138 size.
128 × 128: Assigns to S-Bus space with the switcher
input/output at 128 × 128 size.
3
Set the following parameters.
No.
Parameter
Adjustment
1
Source
Source start address
2
Destination
Destination start address
3
Level
S-Bus space level
Setting External Boxes 1 to 12
To obtain the signal selection status of external devices
with a parallel input, assign a matrix as an external selector
in the S-Bus space. You set the matrix size, assignment
level, source address, and other settings.
1
Open the Engineering Setup >Router/Tally >Router
>External Box Assign menu (7361.1).
2
In the <Device> group, select what the setting applies
to (one of External Box 1 to 12).
3
In the <Matrix Size> group, select the number of
external box inputs.
No Assign: Do not use.
4 × 1: 4 inputs and 1 output.
8 × 1: 8 inputs and 1 output.
16 × 1: 16 inputs and 1 output.
32 × 1: 32 inputs and 1 output.
Notes
The maximum total number of inputs for all 12
external boxes is 102.
4
Set the following parameters.
No.
Parameter
Adjustment
1
Source
Source start address
2
Destination
Destination start address
3
Level
Level
Coupling external boxes
By coupling a number of external boxes, the number of
inputs can be increased.
Here, the example of coupling External Box1 and External
Box2 is described.
1
In the Engineering Setup >Router/Tally >Router
>External Box Assign menu (7361.1), select [External
Box1] from the <Device> group.
2
In the <Matrix Size> group, select [8 × 1].
3
Set the following parameters.