EasyManua.ls Logo

Sony MVS-6520 - Adjusting the Video Clip

Sony MVS-6520
454 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
USO RESTRITO
352
Signal Output Settings
Chapter
19
Switcher
Setup
FC Output 1 and 2
4)
DME Monitor 1 and 2
2) 5)
1)
M/E output signals selected in the M/E Output Assign menu.
2) MVS-6520/6530/3000A only
3)
Makes duplicate assignments if the signal that is assigned is the same
signal as one already assigned to one of Output 1 to xx. However, the
following signals are unavailable if already assigned to Output 1 to
xx.
Out 1 to xx
Multi Viewer 1 and 2
FC Output 1 and 2
DME Monitor 1 and 2
4)
FC Output 1 and 2 can be assigned as a pair combination to Outputs
15 and 16 or Outputs 31 and 32.
5)
MKS-6570 output signal. The output signal is selected in the
Engineering Setup >DME >Output >Monitor Output menu (7343.1)
(
1
p. 364). In addition, the output signal can be displayed
graphically using [Monitor Out] in the DME >Input/Output
>Graphic menu (4164) (
1
p. 172).
3
Select the output connector number and signal to be
assigned.
For output connectors not to be assigned, press
[Inhibit].
4
Press [Set] to confirm the assignment.
Adjusting the Video Clip
1
Open the Engineering Setup >Switcher >Output
>Video Clip menu (7333.2).
2
Select the output you want to set.
3
Adjust the following parameters.
No.
Parameter
Adjustment
2
White Clip
Luminance signal white clip value
3
Dark Clip
Luminance signal dark clip value
4
Chroma Clip
Chrominance signal clip value
To set the values to the default values, press [Default].
Making Vertical Blanking Interval
Adjustment and Through Mode
Settings
This sets the number of scan lines from the reference
blanking position of field 1 for each format that should be
masked.
1
Open the Engineering Setup >Switcher >Output >V
Blank/Through menu (7333.3).
2
Select the output you want to set.
3
Press [V Blank Mask].
4
Adjust the following parameter.
No.
Parameter
Adjustment
2
Mask End
Final value for vertical blanking
interval
a)
a)
Depending on the signal format, the adjustment range varies as
follows.
480i: 10 to 19
576i: 6 to 22
1080i/1080PsF: 7 to 20
720P: 7 to 25
5
To enable through mode, press [Through Mode],
setting it to Enable. The following outputs can be
enabled.
Aux 1 to 24 outputs
Program outputs of the M/E and PGM/PST rows
Clean outputs of the M/E and PGM/PST rows
Making Safe Title Settings
1
Open the Engineering Setup >Switcher >Output >Safe
Title menu (7333.4).
The status area shows the output connectors and the
assigned signals, with the box 1, box 2, cross, and grid
states.
2
Select the output you want to set.
3
To enable the safe title on/off setting made in the Misc
menu, press [Safe Title], turning it on.
4
Carry out one of the following operations.
To display a box: Press [Box1] or [Box2], turning it
on.
In this case, carry out the following steps 5 and 6.
To display a cross: Press [Cross], turning it on.
To display a grid: Press [Grid], turning it on.
In this case, carry out the following steps 5 and 6.
5
If you selected [Box1] or [Box2] in step 4, adjust the
following parameters.
No.
Parameter
Adjustment
2
Box Size
Box size
3
Luminance
Display brightness
a)
a)
Adjustable for Box2
If [Grid] is selected in step 4, in the <Grid Size> group,
select one of the following.
80.00%: Sets the grid size to 80% of the screen frame.
85.00%: Sets the grid size to 85% of the screen frame.

Table of Contents

Other manuals for Sony MVS-6520

Related product manuals