26
MZ-B10
Power Supply Adjustment Auto Item Feed
Note: This mode is available to perform the temperature correction and
power supply adjustment without entering the manual mode.
• Setting method of power supply adjustment auto item feed mode.
1. Set the test mode (see page 16)
2. Press the . key or press the [VOL --] key on the remote
commander to activate the overall adjustment mode.
3. Press the [SPEED CONTROL --] key or the [P MODE] key on
the remote commander to set the temperature correction mode.
4. To change the initial value adjust with the [SPEED CONTROL
+] or [SPEED CONTROL --] key.
Press the X key to write the adjusted value, and the item num-
ber increases automatically.
When not writing the adjusted value, press the > key to move
to the next item.
5. Connect a digital voltmeter to the measuring points on the
MAIN board, and adjust the voltage with the
[SPEED CON-
TROL +] or [SPEED CONTROL --] key. (see page 21 to 24)
Press the X key to write the adjusted value, and the item num-
ber increases automatically.
6. When not writing the adjusted value, press the > key to move
to the next item. The . key is available to back to the last
item.
7. The following message is displayed after all power supply
adjustments finish.
8. Press the x key to return the test mode (display check mode).
• Configuration of power supply adjustment auto item feed
Assy**
000
Set LCD display
SetTmp **
015
Set LCD display
**
: Adjusted value
VC1 L **
741
Set LCD display
**
: Adjusted value