45
[D] System Configuration – SYSTEM CONFIGURATION Menu
Chapter 2 Menu
OFF: Operation mode (default)
ON: Standby mode
POWER ON STATUS: Select the power-up input
channel (LAST or CH).
LAST: Set the channel to the channel that was
selected at the time the power was last turned off
(default).
CH: Set the channel to a specific channel number.
DEFAULT CH: Select the channel (01 to 30) when
the POWER ON STATUS is set to CH (default
setting is 01).
DEGAUSS DELAY: Set the period from the time
when the picture is almost displayed to the
beginning of degaussing (000 to 255) (default
setting is 000). Enter the desired time (in seconds).
[D4] BLANKING SETTINGS... menu
Adjust the data for the blanking.
ANCILLARY DATA: Select whether or not to
display the ancillary data in the serial digital signal
(OFF or ON) (default setting is ON).
VITS BLK: Adjust vertical blanking so that VITS
signals are not visible in the upper part of the
screen.
Set to 000 to 127 (default setting is 000).
[D5] ON SCREEN SET... menu
Set the data about the screen display.
FORMAT DISPLAY: Select the display mode of the
signal system.
AUTO: Disappears after being displayed for a
while (default).
ON: Displayed.
OFF: Not displayed.
POSITION: Select the display position for the signal
system.
TOP LEFT, TOP CENTER, TOP RIGHT,
BOTTOM LEFT (default), BOTTOM CENTER,
BOTTOM RIGHT
CH NO: Select the display mode of the channel
number
AUTO: Disappears after being displayed for a
while (default).
ON: Displayed.
OFF: Not displayed.
POSITION: Select the display position for the
channel number.
TOP LEFT, TOP CENTER, TOP RIGHT (default),
BOTTOM LEFT, BOTTOM CENTER, BOTTOM
RIGHT
CH NAME: Select the display mode of the channel
name
AUTO: Disappears after being displayed for a
while (default).
ON: Displayed.
OFF: Not displayed.
POSITION: Select the display position for the
channel name.
TOP LEFT (default), TOP CENTER, TOP RIGHT,
BOTTOM LEFT, BOTTOM CENTER, BOTTOM
RIGHT
[D6] PASSWORD... menu
Set the password for the menu
Enter four characters. Default setting is “9999”.
CHANGE PASSWORD...: Change the password.
k[D61]
APPLY PASSWORD...: Assign the password to a
menu item. k[D62]
[D61] CHANGE PASSWORD... menu
Change the password.
ENTER NEW PASSWORD: Enter a new password
with the number button and press the ENTER
button. k[D611]
[D611] CHANGE PASSWORD menu
Create a new password.
RE-ENTER PASSWORD: Enter the new password
again and press the ENTER button. The password
is registered.
To change it, press the MENU button.
[D62] APPLY PASSWORD... menu
Select whether or not to apply the password to each menu.
PICTURE ADJ: Select YES or NO.
COLOR TEMP ADJ: Select YES or NO.
INPUT CONFIGURATION: Select YES or NO.
SYSTEM CONFIGURATION: Select YES or NO.
INDIVIDUAL ITEMS...: Display the items of the
SYSTEM CONFIGURATION menu. k[D621]
INSTALLATION SETTINGS: Select YES or NO.
FILE MANAGEMENT: Select YES or NO.
CONTROLLER: Select YES or NO.
KEY PROTECT: Select YES or NO.
[D621] APPLY PASSWORD menu
Select whether or not to apply the password to the
SYSTEM CONFIGURATION menu.
NETWORK: Select YES or NO.
PARALLEL REMOTE: Select YES or NO.
POWER: Select YES or NO.
BLANKING SETTINGS: Select YES or NO.
ON SCREEN SET: Select YES or NO.
[D7] MAINTENANCE... menu
The menu for the maintenance personnel is displayed.