6-2. Up/Down Operation of Head
Set the POSI/NEGA switch to NEGA (a test pattern is printed when this switch is set to POSI). The
PRINT key is used as the head DOWN key, and the COPY key as the head UP key. The head can be put
in the TOP, MIDDLE (home), or BOTTOM position. It can be moved up and down using the PRINT/
COPY key.
6-3. Feed Operation
Press the FEED key. The stepping motor then starts and the platen rotates. The service mode can also be
operated with the door opened. Moreover, the forward and reverse rotations can be switched using the
POSI/NEGA switch. (The platen rotates in the delivery direction when the switch is set to POSI. The
platen rotates in the retracting direction when it is set to NEGA.)
MIDDLE (Home)
PRINT key COPY key
PRINT key COPY key
BOTTOM (Print)
TOP (Door unlocked)