Aer sanizing the machine, DO NOT rinse or touch areas that have been
sanized. Product must be added immediately. If new product will not be added
immediately, rinse machine with clean water and loosen door hand-screws to allow cylinder
to air-dry. Sanize machine before using again.
1. Verify assembly is complete.
2. If installed, remove hopper lid and air
tube.
3. Verify draw valve is in the CLOSED
posion (UP).
4. Mix a minimum of 7.57 liters (2 gallons)
of food-grade sanizer in a bucket or
container.
5. Pour half the food-grade sanizer
soluon into hopper.
6. Turn power switch WASH.
7. Allow soluon to agitate for 5 to 10
minutes; NEVER leave machine on WASH
for more than 10 minutes.
8. While agitang, gently use a clean brush
to scrub and distribute sanizer soluon
along hopper walls .
9. OPEN the draw valve (DOWN) and drain
soluon from the machine.
10. Turn to OFF to stop cycle.

Always use food-grade, no-rinse sanizer to sanize. If warm water is required to
dissolve sanizer, allow the soluon me to cool before adding to machine.


