If machine doesn’t turn on,
turn power OFF, wait 30 minutes,
and repeat steps 1 to 5. If problem
persists, contact service team.
If machine makes any
abnormal noise during reset,
immediately switch power OFF
and contact service team.
-(usually
because the viscosity is set too high for the selected product) to prevent motor damage. Use
the green reset buon to return the machine to normal operaon.

1. Switch power switch OFF.
2. Press green reset buon on side or
back of machine.
3. Wait 15 to 20 minutes; switch power
ON.
4. Press RESET, then WASH buon on
front.
5. Observe machine performance and
return to normal use if funconing
properly.


Make only small adjustments to viscosity seng; allow at least 10 to 15 minutes
between adjustments to evaluate product rmness. Viscosity seng should NOT need
connuous adjustment. A seng of 3 is a good starng point for most product.

Machines without air pumps can experience product consistency changes if they go unused for an ex-
tended period of me. Product may become icy or dense if le in the freezing cylinder too long, oen
occurring during a business’s longer slow-periods.
1. With machine in FREEZE mode, remove air tube.
2. Clean air tube and insert into machine upside-down (inlet hole on the side of the air tube at the top).
3. Conrm product is above low-mix line in hopper.
4. Open draw handle to draw 170 g to 227 g (6 oz. to 8 oz.) of product; discard product.
5. Wait unl machine nishes freeze cycle and motor stops turning.
6. Remove and clean air tube.
7. Insert air tube into machine with correct orientaon (inlet hole on the side of the air tube at the
boom).
8. Machine is ready for normal operaon.
Take O Faceplate
Control Board and Dip Switches



1. Take o faceplate cover by unscrewing le and right
screws from below.
2. Viscosity is adjusted on the Electronic Control Board.
3. Move the switch UP for the desired viscosity level.
Move all other switches DOWN.
4. Viscosity is from Harder to Soer from level 1 - 6.