T200, T380, or T680 Transporter Replacement Install the New Transporter
August 2012 Replacing the Transporter—Spectra T200, T380, and T680 Libraries
21
INSTALL THE NEW TRANSPORTER
Use the following steps to install the new transporter.
1. If necessary, reposition the cartridge picking mechanism on the new
transporter so that it is in its horizontal position.
2. If you are working from the front of the library, move the cartridge
picking mechanism so that it will be toward the front of the library
when you install the transporter.
3. Identify the mounting hooks on the back of the new transporter as well
as the slots in the bracket on the VAX column where the hooks rest.
Note: The mounting bracket on the VAX column may be different from
the one shown in Figure 20.
Figure 19 The transporter mounting hooks
(viewed from the back of the transporter).
Figure 20 The mounting bracket slots on the VAX
column.
Slots
Vertical axis
(VAX) rail
VAX belt