T200, T380, or T680 Transporter Replacement Install the New Transporter
August 2012 Replacing the Transporter—Spectra T200, T380, and T680 Libraries
23
d. Using a 5/32-inch Allen wrench or a 5/32-inch T-handle hex wrench,
loosely install the four screws that secure the transporter to its
mounting bracket.
e. Partially tighten the top two screws until the top of the transporter is
flush against the mounting bracket.
f. Fully tighten the four screws in an “X” pattern. For example, tighten
the top right screw, the bottom left screw, then tighten the bottom
right screw and finally, the top left screw.
Note: To reach the bottom two screws, insert the wrench through the
openings in the side of the transporter.
5. To improve access to the ribbon cable connector on the transporter,
position the transporter and cartridge picking mechanism as follows:
When accessing the transporter from the front of the library:
a. Push on the bottom of the transporter carriage to move the
transporter to the left side of the library.
b. Grasp the edge of the cartridge picking mechanism and gently pull
the mechanism toward you. Leave the cartridge picking mechanism
in the horizontal position.
Be careful not to drop the screws into the transporter or onto any of the internal
components.
Figure 22 Install the screws securing the transporter to the mounting bracket on the VAX column.
Do not use the cartridge picking mechanism as a handle for moving the
transporter.