Operator Manual - Spider ILD02 SG
35 / 51 rev. 01-01-04-2011
11.5 MAINTAINING THE HYDRAULIC
DRIVE
The maintenance of the hydraulic drive requires
properly trained service personnel.
Regular maintenance should address the torque
of hydraulic connections and bolts, replacement
of pressure hoses and oil refilling.
NOTICE:
The maintenance of the hydraulic
parts must be carried out in a very
clean working area. Any
contamination brought into the hydraulic circuit
may cause damage. If replacing any part,
remove all contamination by rinsing it with
cleaning fluid.
NOTICE:
The hydraulic drive must never work
without or with an insufficient
amount of oil, not even for a short
time
11.6 CHECKING AND REFILLING OIL
Check the oil level in the hydraulic oil tank daily.
Measure the oil level with the dipstick in the cap of
the tank. The oil level must be between the limit
marks. If you are working in extreme conditions,
the level of oil (at ambient temperature) must
reach the upper limit mark on the dipstick.
When checking the oil, the engine
must be off and the oil cold.
NOTICE:
If you are checking warm or hot oil, the level of oil
may be higher (and reach above the limit mark)
due to the oil volume expansion.
Do not overfill the hydraulic tank.
11.7 ADJUSTMENT OF THE NEUTRAL POSTION OF THE HYDRAULIC DRIVE
This adjustment should only be performed by an authorised service/dealer.