• Info display
4
• CFG
Enabling
selftuning,
autotuning,
softstart
CFG
Control parameters
Proportional band for
heating or hysteresis on
ON-OFF action
Integral time for heating
Derivative time for
heating
Maximum power limit for
heating
Proportional band for
heating or hysteresis on
ON-OFF action
Proportional band for
cooling or hysteresis on
ON-OFF action
Integral time for cooling
Derivative time for
cooling
Maximum power limit for
cooling
Manual reset
Alarm 2 hysteresis
Alarm 3 hysteresis
Waiting time for HB alarm
intervention
Waiting time for LBA alarm intervention
(Enter “0” to disable LBA alarm)
Power limit for LBA alarm condition
Power output in fault condition
(when probe is faulty)
(*)
(*)
15
16
17
18
19
20
21
22
23
24
25
31
33
34
35
36
S.tun Continuous Selftuning Softstart
Autotuning
0 NO NO NO
1 YES NO NO
2 NO YES NO
3 YES YES NO
4 NO NO YES
5 YES NO YES
6 - - -
7 - - -
8 WAIT NO NO
9 GO NO NO
10 WAIT YES NO
11 GO YES NO
12 WAIT NO YES
13 GO NO YES
0.00 ... 99.99 min
0.00 ... 99.99 min
0.0 ... 100.0%
-999 ... 999
scale points
0 ... 999.9%
full scale
0.00 ... 99.99 min
0.00 ... 99.99 min
0.0 ... 100.0%
± 25.0%
full scale
0 ... 999.9%
full scale
± 999
scale points
± 999
scale points
0 ... 999 sec
0.0 ... 500.0 min
-100.0 ... 100.0%
ON / OFF
-100.0 ... 100.0%
ON / OFF
Setpoint gradient
(see notes)
0.0 ... 999.9 digit / min.
(digit / sec) see SP.ty
Antireset
Feedforward
27
28
0 ... 9999
scale points
-100.0 ... 100.0%
Reset power
26
-100.0 ... 100.0%
Actuator time
(time required by the valve to move from
completely open to completely closed)
0 ... 2000 sec
Minimum pulse time
(useful to reduce mechanical stress of the valve)
0.0 ... 25.0%
Pulsating control band
(set in percentage of opening
valve time)
0.0 ... 100.0%
Dead Band, symmetrical to Setpoint and
selectable in full scale percentage
(when the process value is within this band,
the valve is locked)
Only for valve control type V0, V1, V2
0.0 ... 25.0%
full scale
(*)When the LBA alarm is active, it can be reset by pushing the + keys together when the display
shows the control output value (OutP), or switching the unit to Manual control.
216
207
208
209
210
INFO
Serial
communication
code
Software
version
Software
protection code
Self
diagnostic
error code
8
9
10
11
12
Information
display
0 No Error
1 Lo
2 Hi
3 ERR
4 SBR
Alarm 1 hysteresis
30
± 999
scale points
Softstart time
29
0.0 ... 500.0 min
(The value must be higher than the cycle time of the
output associated to HB alarm)
Minimum power limit for
heating
(not available for double
heat/cool action)
254
0.0 ... 100.0%
Cooling Medium
97
0 ... 2
Cooling power lower limit
(not available for
heating/cooling
double action)
255
0.0 ... 100.0%
C.MEd Relative Gain (rG)
(see applicative note)
0 Air 1
1 Oil 0,8
2 Water 0,4
Remark:
h_Pb, h_it, h_dt, h.P.Hi, hPLo, c_Pb, c_it, c_dt, c.P.Hi, c.P.Lo parameters are “read only” if the option
“control parameter groups” has been selected (showing current values) c_Pb, c_it, c_dt parameters “read
only” if the option “relative gain heat/cool control” (Ctrl = 14) has been selected
-
-
-
-
-
-
-
-
-
-
-
-