8. Install the backplate on the adapter. Check that the seal cup
slot is engaged with the pin on the drive collar.
9. Rotate the backplate until the backplate pins engage the
adapter pins.
10. If supplied, install a water cascade (part no 60112+). Mount
the water cascade (Figure 49, item A) in the adapter above
the seal on the assembled backplate to flow water onto the
sea
l face.
• The connection is 1/4 inch (6
,35 mm) O.D. tubing.
• The required flow is approximately 5 U.S. gallons per
hour (18
,9 liters per hour).
• The recommended water supply is cool and filtered. If the
product solidifies at a cool temperature, use warm or hot
water.
NOTE: Seal Type "F" is a "D" seal with a water cascade
attachment.
11. Rotate the shaft until the pin hole in the end is in a horizon
tal
position. Insert the impeller pin, center it in the shaft end, and
slide the impeller onto the shaft.
NOTE: C-214 shown. C-218 and C-328 impellers have 4
blades.
Figure 47 - Install backplate
Figure 48 - Backplate pins engaged
Figure 49 - Water cascade attachment
Figure 50 - Install impeller