EasyManua.ls Logo

Stanley Labounty MDP Series - Thrust Washer Inspection (MDP 20;27;35;50); MDP 20;27;35;50 Inspection Steps

Stanley Labounty MDP Series
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
24 | MDP Operation & Maintenance Manual
THRUST WASHER INSPECTION - MDP 20/27/35/50
1. Locate at, hard ground and place the attachment on the ground. Ensure the upper jaw is secured and will not fall
during removal.
NEVER remove any pins unless MDP
is on the ground and blocked. Serious
injury or death could result.
2. Remove the front cylinder pin.
Remove Front Cylinder Pin
FIGURE 30
3. Remove the main pivot group, as shown in Figure 31.
END CAP
END CAP
SHIMS
SHIMS
MAIN BEARING
MAIN SHAFT
MAIN BEARING
Remove Main Pivot Group
FIGURE 31

Related product manuals