24 | MDP Operation & Maintenance Manual
THRUST WASHER INSPECTION - MDP 20/27/35/50
1.  Locate at, hard ground and place the attachment on the ground. Ensure the upper jaw is secured and will not fall 
during removal.
•  NEVER remove any pins unless MDP 
is on the ground and blocked. Serious 
injury or death could result.
2.  Remove the front cylinder pin.
Remove Front Cylinder Pin
FIGURE 30 
3.  Remove the main pivot group, as shown in Figure 31.
END CAP
END CAP
SHIMS
SHIMS
MAIN BEARING
MAIN SHAFT
MAIN BEARING
Remove Main Pivot Group