Table 5. Magic Force/Magic Swing Configuration Codes -- Motor 2
Index
Min.
Value
Max.
Value
Description
Defaults
Low Energy Full Energy
20 05 35 Open speed, revoluons per second 06 25
21 03 12 Check speed, revoluons per second 04 04
22 05 40 Stall speed, percent of PWM counts 15 15
23 00 99 Open check length 20 45
24 00 99 Magic Touch sensivity (00 = OFF, 01-99 = sensiv-
ity) (01 = max. sensivity)
00 00
25 00 99 Magic Touch hold open me (25 sec. max. = 99%) 22 16
26 00 99 Hold-open delay in percent (25 sec. max. = 99%) 21 05
27 05 75 Open torque, percent of full torque 25 75
28 05 75 Check torque, percent of full torque 25 40
29 05 75 Stall torque, percent of full torque 25 25
30 00 20 Open Check Boost, transion speed
between braking and check
09 12
31 00 01 Sensor O Mode, 00 - On , 01 O, Ignores sensors
when the funcon switch is o
00 00
32 00 01 Lock Logic – 00 Failsafe , 01 Fail secure – Electric
Strike lock logic
01 01
33 01 60 Obstrucon me in percent (60 = 1.5 seconds) 19 19
34 00 60 Open Acceleraon Slope 60 60
35 20 40 Open Braking Slope 35 35
36 00 50 Operate Delay. Motor 2
(0.1 sec. increments: 5.0 sec. max.)
00 00
37 01 99 Unlock me - E-Strike (99=unlocked unl full closed) 10 10