MC521 PRO Control Box
03.23.2017
1.800.7.ACCESS • www.stanleyaccess.com • Document # 204090 REV D 49
Copyright 2017 Stanley Access Technologies, LLC. All rights reserved. Reproduction
in whole or in part without the express written permission of Stanley is prohibited.
Values shown as grayed out do not aect moon of the door and may need to be adjusted to suit the applicaon
Attachment 10
Table 3 Recommended Values for Single Out-Swing Doors
Index Description Light Weight Door (100lbs) Heavy Weight Doors (350lbs)
Low Energy Full Energy Low Energy Full Energy
00 Open speed, revoluons per second 09 35 05 25
01 Check speed, revoluons per
second
04 05 04 06
02 Stall speed, percent of PWM counts See Aachment 11
03 Open check 20 40 23 50
04 Magic Touch sensivity 00 00 00 00
05 Magic Touch hold open me HH=55
KP=22
HH=40
KP=16
HH=55
KP=22
HH=40
KP=16
HH=55
KP=22
HH=40
KP=16
HH=55
KP=22
HH=40
KP=16
06 Hold-open delay HH=55
KP=22
HH=15
KP=06
HH=55
KP=22
HH=15
KP=06
HH=55
KP=22
HH=15
KP=06
HH=55
KP=22
HH=15
KP=06
07 Open torque, percent of full torque 25 75 25 75
08 Check torque, percent of full torque 25 40 25 75
09 Stall torque, percent of full torque 25 25 25 25
10 Open Check Boost 09 14 09 10
11 Safety Logic 00 00 00 00
12 2S Operaon 00 00 00 00
13 Obstrucon Time HH=50
KP=20
HH=50
KP=20
HH=50
KP=20
HH=50
KP=20
HH=50
KP=20
HH=50
KP=20
HH=50
KP=20
HH=50
KP=20
14 Open Acceleraon Slope 60 60 60 60
15 Open Braking Slope 35 35 35 40
16 Delay of door moon. Motor 1 00 00 00 00
17 No Reverse on Obstrucon 00 NA 00 NA
18 Lock Delay 00 00 00 00
19 Manual Mode sensor override 00 00 00 00
31 O Mode 00 00 00 00
32 Lock Logic 01 01 01 01
37 Unlock Time 10 10 10 10
HH = Hand Held
KP = Key Pad