42
734.843 | 10.48
1
> Yield
Status
Measured values
2
Yield
> Status
Measured values
3
Yield
Status
> Measured values
4
Status
Measured values
> System data
5
Measured values
System data
> Settings
StecaGrid
System
Output
Menu
Enter
Up
Down
Up
Down
Up
Down
Up
Down
Up
Down
After Output
Refresh screen
Enter
Enter
Enter
Enter
Enter
Item
number
Menu item Meaning
1-1-1-1 Current output Shows the current total output of master and
slave units.
1-1-1-2
Highest max. output The highest total output that master and slave
units have reached.
1-1-1-3 Reset highest output Press the Enter button to reset the highest max.
output (1-1-1-2).
1-1-2-1
to
1-1-2-8
Today's date
to
date 7 days ago
The total amount of energy that was produced
by master and slave units on this day.
1-1-3-1
to
1-1-3-13
Current month
to
12 months back
The total amount of energy that was produced
by master and slave units in the relevant month.
1-1-4-1
to
1-1-4-x
Current year
to
year of purchase
The total amount of energy that was produced
by master and slave units in the relevant year.
1-1-5-1 Total energy The total energy that has been produced by
master and slave units since the time of instal-
lation.
1-2-1-1
Current output Shows the power that is present at this moment
(individual readings for the master and slaves).
1-2-1-2
Highest max. output The highest output reached since the system
was last reset (individual reading for the master
and slaves).
1-2-1-3
Resetting the highest max.
output
The highest output of 1-2-1-2 is reset. By press-
ing the Enter button at this menu item, the
output of 1-2-1-2 is the highest output since the
Enter button was pressed at this menu item.
1-2-2-1
to
1-2-2-8
Today's date
to
date 7 days ago
The amount of energy that was produced on
this day (individual readings for master and
slaves).
1-2-3-1
to
1-2-3-13
Current month
to
12 months back
The amount of energy that was produced in the
relevant month (individual readings for master
and slaves).
1-2-4-1
to
1-2-4-x
Current year to year of purchase
(max. 25 years)
The amount of energy that was produced in the
relevant year (individual readings for master and
slaves).
EN

Table of Contents