Loading...
-Removecarburetor,see8.2.2.
Fitgasketinfrontofspacer
flange.
-Setpistontotopdeadcentre
(TDC)(canbeseenthroughthe
inletport).
-Checkthatsparkplugisseated
securely.
Fittestflange(1)11288504200.
Fitandtightennuts(2).
-Removeouterscrewonmuffler.
-Backoffinnerscrewshalf-way.
Slidesealingplate(1)
00008558106betweengasket
andcylinderexhaustportand
lightlyretighteninnerscrews.
Note:Thesealingplatemustfill
thespacebetweenthemounting
screwscompletely.
-Carryoutpreparatorysteps,
see4.2.1.
Slidepressurehoseoftester
11068502905overnippleon
testflange.
Closeventscrew(1)onrubber
bulb.
-Pumpairintocrankcasewith
rubberbulbuntilpressuregauge
indicatesapressureof0.5bar.
Thecrankcaseisairtightifthis
pressureremainsconstantforat
least20seconds.
4.2.1 Preparations 4.2.2 Pressuretest