45MS 440, MS 440 C
– Remove the shroud – b 6.4
– Remove the fan housing with
rewind starter – b 8.2
: Pull the short-circuit wire (1) off
the ignition module and pry it out
of the retainer (2).
VA
176RA152
1
2
: Take out the screws (arrows).
– Remove the ignition module.
VA
176RA153
If the ignition lead or spark plug boot
is damage, install new parts –
b 7.2
– Press the lugs of the retainer
outwards if necessary.
: Remove the retainer.
– Connect the ignition lead if
necessary before proceeding
with installation – b 7.2
VA
176RA154
: On machines with handle
heating, route the wire through
the retainers (arrows).
VA
176RA150
– Install the ignition module.
On machines with handle heating,
the plug connection from the
generator must be routed under the
ignition module.
– Coat the screw threads with
VA
176RA153
Loctite 242 – b 16.
Fit the ground wire under the right-
hand screw of the ignition module.
: Tighten down the screws
moderately (arrows).
7.1.2 Removing and Installing